CAEL-LGN Cartridge Sun Hydraulics
Sun Counterbalance Valve T-2A Cavity 2:1 pilot ratio, vented counterbalance valve - atmospherically referenced
Sun Counterbalance Valve T-11A Cavity 3:1 pilot ratio, standard capacity counterbalance valve
Certificados en SSL tus compras están protegidas
Envíos a $65 en Nuevo Leon. Enviamos a toda la República Mexicana por FedEx desde $115.
Todos tus pedidos serán facturados, somos una empresa formalmente constituida.
¿Dudas, Producto Especial? Tenemos la solución raíz ¡Cotiza con nosotros! Ventas@Traser.com.mx
Counterbalance valves with pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting, pilot-assisted relief valve controls flow from port 1 to port 2. Pilot assist at port 3 lowers the effective setting of the relief valve at a rate determined by the pilot ratio. Other names for this valve include motion control valve and over-center valve. Counterbalance valves should be set at least 1.3 times the maximum load induced pressure. Turn adjustment clockwise to decrease setting and release load. Full clockwise setting is less than 200 psi (14 bar). Backpressure at port 2 adds to the effective relief setting at a ratio of 1 plus the pilot ratio times the backpressure. Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages. This valve does not have positive seals on the pilot section and will pass up to 3 in_/min.@1000 psi (45 ml/min.@70 bar ) between port 2 and port 3. This is a consideration in master-slave circuits and in the leak testing of valve-cylinder assemblies. Cartridges configured with EPDM seals are for use in systems with phosphate ester fluids. Exposure to petroleum based fluids, greases and lubricants will damage the seals. Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit. Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern. All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). Corrosion resistant cartridge valves are intended for use in corrosive environments and are identified by the model code suffix /AP for external stainless steel components, or /LH for external zinc-nickel plated components. See the CONFIGURATION section for all options. For further details, please see the Materials of Construction page located under TECH RESOURCES. Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge machining variations.
Referencias Específicas
No customer reviews for the moment.
Sun Counterbalance Valve T-2A Cavity 2:1 pilot ratio, vented counterbalance valve - atmospherically referenced
Sun Counterbalance Valve T-17A Cavity 10:1 pilot ratio, standard capacity counterbalance valve
Sun Pilot Check Valve T-11A Cavity Vented pilot-to-open check valve - atmospherically referenced
Sun Counterbalance Valve T-2A Cavity 3:1 pilot ratio, standard capacity counterbalance valve
Sun Counterbalance Valve T-11A Cavity 3:1 pilot ratio, standard capacity counterbalance valve
Sun Counterbalance Valve T-19A Cavity 2:1 pilot ratio, vented counterbalance valve - atmospherically referenced
Sun Counterbalance Valve T-2A Cavity Standard capacity counterbalance valve without pilot assist
Sun Pilot Check Valve T-11A Cavity Pilot-to-open check valve with standard pilot
Sun Counterbalance Valve T-17A Cavity 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced
Sun Counterbalance Valve T-11A Cavity 4.5:1 pilot ratio, standard capacity counterbalance valve
Sun Counterbalance Valve T-11A Cavity 3:1 pilot ratio, restrictive counterbalance valve
Sun Counterbalance Valve T-2A Cavity 4.5:1 pilot ratio, standard capacity counterbalance valve
Sun Counterbalance Valve T-11A Cavity 4.5:1 pilot ratio, standard capacity counterbalance valve
Sun Counterbalance Valve T-19A Cavity 10:1 pilot ratio, standard capacity counterbalance valve
Sun Counterbalance Valve T-2A Cavity 4.5:1 pilot ratio, standard capacity counterbalance valve
Sun Counterbalance Valve T-17A Cavity Standard capacity counterbalance valve without pilot assist