CAIA-LIN Cartridge Sun Hydraulics
Sun Counterbalance Valve T-19A Cavity 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced
Sun Counterbalance Valve T-17A Cavity Standard capacity counterbalance valve without pilot assist
Certificados en SSL tus compras están protegidas
Envíos a $65 en Nuevo Leon. Enviamos a toda la República Mexicana por FedEx desde $115.
Todos tus pedidos serán facturados, somos una empresa formalmente constituida.
¿Dudas, Producto Especial? Tenemos la solución raíz ¡Cotiza con nosotros! Ventas@Traser.com.mx
Counterbalance valves without pilot assist are meant to control an overrunning load. The check valve allows free flow from the directional valve (port 2) to the load (port 1) while a direct-acting relief valve controls flow from port 1 to port 2. Counterbalance valves should be set at least 1.3 times the maximum load induced pressure. Turn adjustment clockwise to decrease setting and release load. Full clockwise setting is less than 200 psi (14 bar). These valves are modified versions of our pilot assisted counterbalance valves. The pilot assist area has been nullified internally. There is no connection to port 3. Backpressure at port 2 is directly additive to the relief setting of the valve. Lower pilot ratios (pilot gain) promote machine stability. This valve has a pilot ratio of zero. Stability is gained at the expense of efficiency. Reseat exceeds 85% of set pressure when the valve is standard set. Settings lower than the standard set pressure may result in lower reseat percentages. All 3-port counterbalance, load control, and pilot-to-open check cartridges are physically interchangeable (i.e. same flow path, same cavity for a given frame size). Sun counterbalance cartridges can be installed directly into a cavity machined in an actuator housing for added protection and improved stiffness in the circuit. Two check valve cracking pressures are available. Use the 25 psi (1,7 bar) check unless actuator cavitation is a concern.
Referencias Específicas
No customer reviews for the moment.
Sun Counterbalance Valve T-19A Cavity 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced
Sun Counterbalance Valve T-19A Cavity 3:1 pilot ratio, standard capacity counterbalance valve
Sun Counterbalance Valve T-11A Cavity 3:1 pilot ratio, semi-restrictive counterbalance valve
Sun Counterbalance Valve T-11A Cavity 3:1 pilot ratio, standard capacity counterbalance valve
Sun Back to Back CheckValve T-11A Cavity Back-to-back check/shuttle valve with signal at port 3
Sun Counterbalance Valve T-2A Cavity 1.5:1 pilot ratio, standard capacity counterbalance valve
Sun Counterbalance Valve T-2A Cavity 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced
Sun Counterbalance Valve T-2A Cavity 4.5:1 pilot ratio, standard capacity counterbalance valve
Sun Pilot Check Valve T-11A Cavity Pilot-to-open check valve with standard pilot
Sun Counterbalance Valve T-19A Cavity 3:1 pilot ratio, standard capacity counterbalance valve
Sun Counterbalance Valve T-11A Cavity 3:1 pilot ratio, restrictive counterbalance valve
Sun Counterbalance Valve T-19A Cavity 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced
Sun Pilot Check Valve T-2A Cavity Pilot-to-open check valve with standard pilot
Sun Counterbalance Valve T-17A Cavity 3:1 pilot ratio, vented counterbalance valve - atmospherically referenced